
Automatic Fire Extinguishers - ABC Powder (Wall Mounted)
Ceasefire’s Automatic Fire Extinguisher (Wall Mounted) addresses two simple problems; first of fire safety and second of space crunch. Being an automatic extinguisher it is ideal for spaces like boats and engine compartments that are not just prone to fire but also have limited space, where installing an extinguisher can be a challenge.
Ceasefire Automatic Fire Extinguishers (Wall Mounted) come equipped with wall mounting brackets that make it extremely easy to install the extinguisher on the wall. The Extinguisher is available in ABC Powder (MAP 50 and MAP 90) making it ideal for a wide range of applications.
What makes the extinguisher even more versatile is the optional telescopic mounting mechanism that can make the extinguisher reach closest to the area of threat. This makes it capable of protecting specific spots or assets that are at high fire risk.
Ceasefire Automatic Fire Extinguisher (Wall Mounted) is a one of-a-kind extinguisher that works as a standalone, modular suppression system. Ensuring that no fire goes undetected and unaddressed. The biggest pro of this advanced extinguisher is that it eliminates the need to manually address the fire.
The thermal actuator detects the rising temperature of the area and activates automatically, even when no one is around, ensuring that the fire is brought under control early and efficiently.
The optional telescopic arms of the Automatic Fire Extinguisher (Wall Mounted) bring the extinguishers closer to the threat and guard the targeted areas that are at high fire risk. Ultimately, improving the chance of early fire detection and effective fire fighting.
Ceasefire Automatic Fire Extinguishers (Wall Mounted) come in 1Kg, 2Kg, 4Kg, 6Kg and 9Kg size options in Mild Steel containers to address a wide variety of applications.
-
Classification: Works on all classes of fire.
-
24x7 protection: Automatic detection and suppression.
-
Mounting bracket: Comes with a secure mounting bracket for direct installation on the wall.
-
Optional mounting bracket: Optional flexible mounting bracket that enables optimal positioning of the extinguisher in the risk zone for targeted protection.
-
10-year Warranty: 10-year Warranty means Ceasefire is looking out for the health of your fire safety products.
-
GLOSSARY INVERTED AUTOMATIC FIRE EXT MAP50 1KG MS SP RED INVERTED AUTOMATIC FIRE EXT MAP50 2KG MS SP RED INVERTED AUTOMATIC FIRE EXT MAP50 4KG MS SP RED INVERTED AUTOMATIC FIRE EXT MAP50 6KG MS SP RED INVERTED AUTOMATIC FIRE EXT MAP50 9KG MS SP RED PRODUCT CODES CF-001401 CF-001402 CF-001403 CF-001404 CF-001405 AGENT ABC POWDER MAP 50 ABC POWDER MAP 50 ABC POWDER MAP 50 ABC POWDER MAP 50 ABC POWDER MAP 50 STORED PRESSURE/CARTRIDGE STORED PRESSURE STORED PRESSURE STORED PRESSURE STORED PRESSURE STORED PRESSURE CERTIFICATION OR VERIFING BODY EUROCERT EUROCERT EUROCERT EUROCERT EUROCERT CERTIFICATION TYPE PED PED PED PED PED CE MARKING/UK CA CE YES YES YES YES YES COVERAGE AREA (MAXIMUM) 1.6 SQUARE METER 2.3 SQUARE METER 6.3 SQUARE METER 9.8 SQUARE METER 19.2 SQUARE METER GROSS WEIGHT (APPROX) 1.8 KG 3.3 KG 6 KG 8.7 KG 12.9 KG NET MASS 0.8KG 1.3KG 1.9KG 2.6KG 3.8KG DISCHARGE MECHANISM AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC APPLICABLE ON FIRES A, B, C, & ELECTRICAL STARTED FIRE A, B, C, & ELECTRICAL STARTED FIRE A, B, C, & ELECTRICAL STARTED FIRE A, B, C, & ELECTRICAL STARTED FIRE A, B, C, & ELECTRICAL STARTED FIRE CAN CONSTRUCTION DEEP DRAWN & MIG WELDED DEEP DRAWN & MIG WELDED DEEP DRAWN & MIG WELDED DEEP DRAWN & MIG WELDED DEEP DRAWN & MIG WELDED VALVE / CAP CONSTRUCTION FORGING AND MACHINING FORGING AND MACHINING FORGING AND MACHINING FORGING AND MACHINING FORGING AND MACHINING EXTERNAL COATING EPOXY POLYESTER POWDER EPOXY POLYESTER POWDER EPOXY POLYESTER POWDER EPOXY POLYESTER POWDER EPOXY POLYESTER POWDER HELIUM LEAK DETECTION TESTING YES YES YES YES YES WARRANTY IN YEARS 10 10 10 10 10 WORKING PRESSURE 15 BAR 15 BAR 15 BAR 15 BAR 15 BAR HYDROSTATIC TEST PRESSURE 30 BAR 30 BAR 30 BAR 30 BAR 30 BAR (APPROX)DIA. OF SHELL (OD) 86.5 MM 108 MM 140 MM 160 MM 175 MM HEIGHT OF FIRE EXT. (APPROX) 330 MM 350 MM 396 MM 446 MM 577 MM BODY THICKNESS (APPROX) 1 MM 1.4 MM 1.2 MM 1.4 MM 1.4 MM CYLINDER MATERIAL SPEC. STEEL CR2(DC01) STEEL CR2(DC01) STEEL CR2(DC01) STEEL CR2(DC01) STEEL CR2(DC01) OPERATING TEMPERATURE DEFAULT 79 °C DEFAULT 79 °C DEFAULT 79 °C DEFAULT 79 °C DEFAULT 79 °C * Available in other temperature 68° C & 93° C on request.
GLOSSARY INVERTED AUTOMATIC FIRE EXT MAP90 1KG MS SP RED INVERTED AUTOMATIC FIRE EXT MAP90 2KG MS SP RED INVERTED AUTOMATIC FIRE EXT MAP90 4KG MS SP RED INVERTED AUTOMATIC FIRE EXT MAP90 6KG MS SP RED INVERTED AUTOMATIC FIRE EXT MAP90 9KG MS SP RED PRODUCT CODES CF-001406 CF-001407 CF-001408 CF-001409 CF-001410 AGENT ABC POWDER MAP 90 ABC POWDER MAP 90 ABC POWDER MAP 90 ABC POWDER MAP 90 ABC POWDER MAP 90 STORED PRESSURE/CARTRIDGE STORED PRESSURE STORED PRESSURE STORED PRESSURE STORED PRESSURE STORED PRESSURE CERTIFICATION OR VERIFING BODY EUROCERT EUROCERT EUROCERT EUROCERT EUROCERT CERTIFICATION TYPE PED PED PED PED PED CE MARKING/UK CA CE YES YES YES YES YES COVERAGE AREA (MAXIMUM) 1.6 SQUARE METER 2.3 SQUARE METER 6.3 SQUARE METER 9.8 SQUARE METER 19.2 SQUARE METER GROSS WEIGHT (APPROX) 1.8 KG 3.3 KG 6 KG 8.7 KG 12.9 KG NET MASS 0.8 KG 1.3 KG 1.9 KG 2.6 KG 3.8 KG DISCHARGE MECHANISM AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC APPLICABLE ON FIRES A, B, C, & ELECTRICAL STARTED FIRE A, B, C, & ELECTRICAL STARTED FIRE A, B, C, & ELECTRICAL STARTED FIRE A, B, C, & ELECTRICAL STARTED FIRE A, B, C, & ELECTRICAL STARTED FIRE CAN CONSTRUCTION DEEP DRAWN & MIG WELDED DEEP DRAWN & MIG WELDED DEEP DRAWN & MIG WELDED DEEP DRAWN & MIG WELDED DEEP DRAWN & MIG WELDED VALVE / CAP CONSTRUCTION FORGING AND MACHINING FORGING AND MACHINING FORGING AND MACHINING FORGING AND MACHINING FORGING AND MACHINING EXTERNAL COATING EPOXY POLYESTER POWDER EPOXY POLYESTER POWDER EPOXY POLYESTER POWDER EPOXY POLYESTER POWDER EPOXY POLYESTER POWDER HELIUM LEAK DETECTION TESTING YES YES YES YES YES WARRANTY IN YEARS 10 10 10 10 10 WORKING PRESSURE 15 BAR 15 BAR 15 BAR 15 BAR 15 BAR HYDROSTATIC TEST PRESSURE 30 BAR 30 BAR 30 BAR 30 BAR 30 BAR DIA. OF SHELL (OD) 86.5 MM 108 MM 140 MM 160 MM 175 MM HEIGHT OF FIRE EXT. (APPROX) 330 MM 350 MM 396 MM 446 MM 577 MM BODY THICKNESS (APPROX) 1 MM 1.4 MM 1.2 MM 1.4 MM 1.4 MM CYLINDER MATERIAL SPEC. STEEL CR2(DC01) STEEL CR2(DC01) STEEL CR2(DC01) STEEL CR2(DC01) STEEL CR2(DC01) OPERATING TEMPERATURE DEFAULT 79 °C DEFAULT 79 °C DEFAULT 79 °C DEFAULT 79 °C DEFAULT 79 °C * Available in other temperature 68° C & 93° C on request.
